Saltar al contenido
República del Perú · Observatorio de la producción científica universitaria
OApol.org Observatorio de Inteligencia Científica Universitaria del Perú
OApol.org
Inicio Universidades Publicaciones Investigadores
Repositorios
Tesis y trabajos académicosRevistas
Indicadores
Ranking trimestralRanking por carreraObjetivos de Desarrollo SostenibleReporte OCDERed neuronal 3D
Acerca
MetodologíaPrivacidad

Microbiological characterization and antimicrobial resistance of two surfaces of Veterinarians’ stethoscopes in Trujillo, Perú

De Lima-Núñez T.A.; Ramírez-Reyes R.P. · Archives of Veterinary Science (2025) · DOI: 10.5380/avs.v30i2.98214

Resumen

The stethoscope is a medical instrument used daily for physical examinations, whose capacity as a fomite remains underexplored in veterinary medicine. This study aims to identify the main bacteria isolated from the stethoscopes of veterinarians in Trujillo (Peru) and to identify the factors associated with the presence of these pathogens through microbiological analysis and the application of a questionnaire. Fifty-nine stethoscopes were sampled using sterile swabs soaked in BHI broth (Brain Heart Infusion) and rubbed 4 times at different locations opposite the previous one. The surfaces sampled were chest pieces and ear tips. After being incubated for 24 hours at 37°C, the sample were cultured on blood agar, and after the bacterial morphology was identified, biochemical tests were performed. Results showed that 88% of stethoscopes were contaminated, yielding 100 isolates (8 genera). Staphylococcus aureus (35%) was the most frequently isolated species, followed by Coagulase-negative Staphylococcus (34%) and Pseudomonas spp. (18%). Notably, high levels of antimicrobial resistance were observed, with S. aureus exhibiting 94.3% resistance to penicillin and 80% to tetracycline. The chest piece was the most contaminated surface (95%; 56/59). A statistical association was found between disinfection practices and bacterial presence (p<0.05), with non-disinfection identified as a risk factor (OR=1.636; 95% CI=1.132-2.366). The above shows that veterinary stethoscopes, often contaminated with bacteria linked to nosocomial infections, require effective disinfection protocols and robust antimicrobial stewardship programs to mitigate the spread of multidrug-resistant bacteria, protect patient and user health, and preserve antibiotic efficacy in the long term. © (2024), (Universidade Federal do Parana). All Rights Reserved.

Instituciones: Universidad Privada Antenor Orrego