Measurement of Shielding Effectiveness in Coaxial Cables and Connectors With Various Dielectrics Using an Electric Field Probe
Santos K.M.G.; Perotoni M.B.; Silva E.P.; Santos A.M.; Novo M.S.; Silveira T.M.; Santos P.A.; Faria D.R.M.; Lima R.M.; Caires L.S.; Gallego M.R.; Tavares S.M.O.; Moreira R.A.S. · IEEE Transactions on Dielectrics and Electrical Insulation (2025) · DOI: 10.1109/tdei.2025.3557368
Resumen
Ensuring proper shielding is essential for the electromagnetic compatibility of electronic devices and systems. This article investigates the shielding effectiveness (SE) of coaxial cables and connectors using an electric field probe (EFP). This study aims to identify shielding failures early to prevent costly fixes later. A method for measuring the electric field radiated by connectors and cables in both near-field and far-field conditions is presented. Additionally, an electromagnetic virtual model of the connector and cable is developed, incorporating the dimensions and properties of the dielectric material. The simulations focus on the impact of different dielectrics on the resonant frequency of the electric field, specifically common-mode energy. The results indicate that the dielectric properties do not affect the resonant frequency in the presence of a common-mode current distribution.