Saltar al contenido
República del Perú · Observatorio de la producción científica universitaria
OApol.org Observatorio de Inteligencia Científica Universitaria del Perú
OApol.org
Inicio Universidades Publicaciones Investigadores
Repositorios
Tesis y trabajos académicosRevistas
Indicadores
Ranking trimestralRanking por carreraObjetivos de Desarrollo SostenibleReporte OCDERed neuronal 3D
Acerca
MetodologíaPrivacidad

Low-cost portable system for measuring thermal conductivity of building

Palo-Tejada E.; Puma A.; Campos-Falcon V.; Guzman A.; Perez R.; Tunti J. · Journal of Physics: Conference Series (2022) · DOI: 10.1088/1742-6596/2180/1/012002

Resumen

The developed system allows to measure the thermal conductivity of solid materials used as thermal insulators in building bioclimatic houses on high Andean zones. A unidirectional heat flow model through a sample of dimensions 4.0 cm x 4.2 cm x 1.35 cm has been considered. K-type thermocouples were used to measure the temperature's gradient. The obtained values were: 0.97 Wm-1°C-1 for glass, 0.38 Wm-1°C-1 in the ignimbrite, 0.58 Wm-1°C-1 for the roof brick and 0.34 Wm-1°C-1 in the adobe with Stipa ichu. These materials have been evaluated considering their abundance and use in house building on the Arequipa department high zones. © Published under licence by IOP Publishing Ltd.

Instituciones: Universidad Nacional de San Agustín de Arequipa