Assessing 3 outbreak detection algorithms in an electronic syndromic surveillance system in a resource-limited setting
Alsentzer E.; Ballard S.-B.; Neyra J.; Vera D.M.; Osorio V.B.; Quispe J.; Blazes D.L.; Loayza L. · Emerging Infectious Diseases (2020) · DOI: 10.3201/eid2609.191315
Resumen
We evaluated the performance of X-bar chart, exponentially weighted moving average, and C3 cumulative sums aberration detection algorithms for acute diarrheal disease syndromic surveillance at naval sites in Peru during 2007-2011. The 3 algorithms' detection sensitivity was 100%, specificity was 97%-99%, and positive predictive value was 27%-46%.